  1. Quick imaging?Imaging time below 6S to meet large-scale medical examination requirements.
  2. Image replay?Image thumbnail display, sequence playback tool, digital image replay.
  3. Image processing?Window width/window position adjustment, arrow, text and other labels, angle, distance measurement, image zoom, pan, left and right flip, up and down, rotation, black and white inversion, shadow screen selection.
  4. Image storage?Image real-time storage, DICOM image sending, disc burning, export storage (optional in a variety of storage formats: Bitmap, Jepg, AVI and other office software directly used in Word and PowerPoint, convenient for doctors to diagnose reports and paper writing.
  5. DICOM 3.0?Perfect compatibility with brand laser cameras and PACS systems.
  6. Medical records management?Database management, graphic reporting, support for WORKLIST.

Compare
in stock

Description

Specification

 

Product model Part name and model AR-960-I
X-ray generation device High-pressure trigger FSYG60 1
X-ray tube LQ16-XA4 1
High-voltage cable GD-1 2
 

 

X-ray imaging system

Flat-panel detector DR 17/17 1
DR 14/17 /
Computer DR-1000 1
Display unit XS-1000 1
Software systems DR-1000 1
Subsidiary equipment Photo bed SYC-2 1
Chest support SPJ-2 1

 

 

Product performance and parameters?

X-ray generation device High frequency reversal frequency: no less than 120kHz
Maximum output power?

Photo: a) P should be 100KV, 500mA, 50kW (large focus)

b) P should be 110KV, 160mA, 17.6KW (small focus)

X-ray tube voltage: tube voltage regulation range: 40 kV to 150 kV, 1 kV per step
X-ray tube current: photographic tube current regulation range: 10mA-630mA, split adjustment mode, selected by national standard: GB9706 r10 coefficient
Tube current: tube current product adjustment range: 1mAs-1000mA, the current product using split adjustment mode, according to national standards: GB9706 r20 coefficient selection;
Anti-overload: X-ray machine has anti-overload measures
Photo preparation time: Photo preparation time should not be greater than 1s
X-ray imaging system Network communications: DICOM 3.0 compliant
Amorphous silicon flat panel detector DR 17/17 No less than 430 mm x 430 mm (17 in x 17 inches)
Amorphous silicon full board seamless, ultra-thin design, thickness and box size of

15mm

Image spatial resolution should be no less than 3.6 LP/mm
Software: user management, capture images, exposure, image preview, image processing, image measurement, image printing
Subsidiary equipment Photo bed Photo bed surface, left and right range is not less than 900mm, front and? rear range of motion is not less than 320mm

 

Ball tube can be used left and right movement stroke should not be less than 1200mm, up and down movement trip should not be less

than 1000mm

?The Focus distance of the X-ray tube to the flat plate detector is no less than 1200mm