AR-203 Ventilator (Air Compressor)
<table width="643"> <tbody> <tr> <td colspan="3" width="643"><strong>SECURITY ALARM SYSTEM </strong></td> </tr> <tr> <td rowspan="2" width="208">Oxygen Concentration Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">21%~100%</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">10%~80%</td> </tr> <tr> <td rowspan="2" width="208">Airway Pressure Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">0.3~6.0 kPa</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0.2~5.0 kPa</td> </tr> <tr> <td rowspan="2" width="208">Per-minute Ventilation Volume Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">3.0~30L/min</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">1.0~10L/min</td> </tr> <tr> <td rowspan="2" width="208">Respiratory Rate</td> <td width="217">Upper Limit Setting Range</td> <td width="217">50~99bpm</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0~50bpm</td> </tr> <tr> <td rowspan="2" width="208">Tidal Volume</td> <td width="217">Upper Limit Setting Range</td> <td width="217">10~2000ml</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0~1800ml</td> </tr> <tr> <td width="208">Sustained High-pressure Alarm</td> <td colspan="2" width="435">It will give alarm when stress have consistently been higher than 2.5kPa.</td> </tr> <tr> <td width="208">Suffocation Alarm</td> <td colspan="2" width="435">It will give sound and light alarm if there is no tidal volume input for 15 seconds.</td> </tr> <tr> <td colspan="3" width="643">Power Alarm; Gas Shortage Alarm; Intubation off Alarm</td> </tr> </tbody> </table> <h2></h2>
AR-203 Ventilator (Air Compressor)
<table width="643"> <tbody> <tr> <td colspan="3" width="643"><strong>SECURITY ALARM SYSTEM </strong></td> </tr> <tr> <td rowspan="2" width="208">Oxygen Concentration Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">21%~100%</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">10%~80%</td> </tr> <tr> <td rowspan="2" width="208">Airway Pressure Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">0.3~6.0 kPa</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0.2~5.0 kPa</td> </tr> <tr> <td rowspan="2" width="208">Per-minute Ventilation Volume Alarm</td> <td width="217">Upper Limit Setting Range</td> <td width="217">3.0~30L/min</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">1.0~10L/min</td> </tr> <tr> <td rowspan="2" width="208">Respiratory Rate</td> <td width="217">Upper Limit Setting Range</td> <td width="217">50~99bpm</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0~50bpm</td> </tr> <tr> <td rowspan="2" width="208">Tidal Volume</td> <td width="217">Upper Limit Setting Range</td> <td width="217">10~2000ml</td> </tr> <tr> <td width="217">Low Limit Setting Range</td> <td width="217">0~1800ml</td> </tr> <tr> <td width="208">Sustained High-pressure Alarm</td> <td colspan="2" width="435">It will give alarm when stress have consistently been higher than 2.5kPa.</td> </tr> <tr> <td width="208">Suffocation Alarm</td> <td colspan="2" width="435">It will give sound and light alarm if there is no tidal volume input for 15 seconds.</td> </tr> <tr> <td colspan="3" width="643">Power Alarm; Gas Shortage Alarm; Intubation off Alarm</td> </tr> </tbody> </table> <h2></h2>
AR-960-I High Frequency Digital Radiography System (DR)
<h2>Professional medical image processing software</h2> <ol> <li>Quick imaging?Imaging time below 6S to meet large-scale medical examination requirements.</li> <li>Image replay?Image thumbnail display, sequence playback tool, digital image replay.</li> <li>Image processing?Window width/window position adjustment, arrow, text and other labels, angle, distance measurement, image zoom, pan, left and right flip, up and down, rotation, black and white inversion, shadow screen selection.</li> <li>Image storage?Image real-time storage, DICOM image sending, disc burning, export storage (optional in a variety of storage formats: Bitmap, Jepg, AVI and other office software directly used in Word and PowerPoint, convenient for doctors to diagnose reports and paper writing.</li> <li>DICOM 3.0?Perfect compatibility with brand laser cameras and PACS systems.</li> <li>Medical records management?Database management, graphic reporting, support for WORKLIST.</li> </ol>
AR-960-I High Frequency Digital Radiography System (DR)
<h2>Professional medical image processing software</h2> <ol> <li>Quick imaging?Imaging time below 6S to meet large-scale medical examination requirements.</li> <li>Image replay?Image thumbnail display, sequence playback tool, digital image replay.</li> <li>Image processing?Window width/window position adjustment, arrow, text and other labels, angle, distance measurement, image zoom, pan, left and right flip, up and down, rotation, black and white inversion, shadow screen selection.</li> <li>Image storage?Image real-time storage, DICOM image sending, disc burning, export storage (optional in a variety of storage formats: Bitmap, Jepg, AVI and other office software directly used in Word and PowerPoint, convenient for doctors to diagnose reports and paper writing.</li> <li>DICOM 3.0?Perfect compatibility with brand laser cameras and PACS systems.</li> <li>Medical records management?Database management, graphic reporting, support for WORKLIST.</li> </ol>
ARI-100 High Frequency Mobile X-ray Equipment
<h4>Purpose</h4> The equipment is a combined high frequency X-ray video camera that can be conveniently moved to wards, ICU, operating rooms and so on for taking film. <strong>?</strong> <h4>Features</h4> <ol> <li>Structure designed based on anthropotomy, with beautiful appearance, and easy to operate.</li> <li>Colorful Touch LCD display, human graphic controller to adjust parameters, multifunction of safety guard.</li> <li>With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.</li> <li>With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.</li> <li>It is featured with protection for shortage of high voltage, over-flowing of tube current and output over-loading as well as indication for failure.</li> <li>With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.</li> </ol>
ARI-100 High Frequency Mobile X-ray Equipment
<h4>Purpose</h4> The equipment is a combined high frequency X-ray video camera that can be conveniently moved to wards, ICU, operating rooms and so on for taking film. <strong>?</strong> <h4>Features</h4> <ol> <li>Structure designed based on anthropotomy, with beautiful appearance, and easy to operate.</li> <li>Colorful Touch LCD display, human graphic controller to adjust parameters, multifunction of safety guard.</li> <li>With a high-quality knockdown X-ray generator to reduce irradiation, which is much safer to environment and operator.</li> <li>With 50 preset exposure programs, and can be modified and stored by the user for convenient operation.</li> <li>It is featured with protection for shortage of high voltage, over-flowing of tube current and output over-loading as well as indication for failure.</li> <li>With a symmetrical beam applicator to adjust the X-ray field and a collimator lamp to locate the filed to ensure accurate radiograph.</li> </ol>
Auto Electrolyte Analyzer BKE Series
Features: <ol> <li>. Automatic electric potential tracking and correcting software.</li> <li>. Automatically detect and filter tiny bubbles.</li> <li>Real-time diagnostic of system working status.</li> <li>Waste liquid automatic detection and alarming.</li> <li>Automatic calibration and two-point correction.</li> <li>Wave theory flushing method and direct flushing pipe method.</li> <li>High accurate and long life electrode and? TC02 sensor.</li> <li>Sleep mode to reduce reagent consumption.</li> <li>Rapid test speed of 80 tests per hot-IL</li> <li>Option: Sample tray.</li> </ol>
Auto Electrolyte Analyzer BKE Series
Features: <ol> <li>. Automatic electric potential tracking and correcting software.</li> <li>. Automatically detect and filter tiny bubbles.</li> <li>Real-time diagnostic of system working status.</li> <li>Waste liquid automatic detection and alarming.</li> <li>Automatic calibration and two-point correction.</li> <li>Wave theory flushing method and direct flushing pipe method.</li> <li>High accurate and long life electrode and? TC02 sensor.</li> <li>Sleep mode to reduce reagent consumption.</li> <li>Rapid test speed of 80 tests per hot-IL</li> <li>Option: Sample tray.</li> </ol>
B19 Breathing Therapy System
<h2>Features</h2> <ol> <li>5"TFT LCD display with easy operation.</li> <li>Interactive operation interface is available. Back-lighting function allow night operation.</li> <li>Fashionable design with fine piano lacquer, convenient for wipe.</li> <li>Respiratory waveform & quality waveform display can achieve real time monitoring of CPAP</li> <li>Ultra-silent design & Delay time step up design.</li> <li>The portable machine adopts imported movement technology, capable of constant heating.</li> <li>Bipap machine is working to achieve human-computer synchronization.</li> </ol> <h2>Notes of CPAP Machine</h2> <ol> <li>Not available in bullous lung disease, pneumothorax, severe lack of effective circulating blood volume with shock, coma or with disturbance of consciousness, or don?t cooperate or accept the mask treatment.</li> <li>Not apply to children, or physical, sensory, intellectual cannot be used safely and without the aid or user under guardianship.</li> </ol>